High Efficiency≧94%
@ 50% load
CRPS Form Factor
N+1 Redundancy with Load Sharing Capability
PMBus monitoring and control |
Dimension: 73.5x39x185mm
Input Range : 90 to 264Vac or 192 to 288Vdc
Power Factor: ≧0.95 minimum at full load
Hold up Time: 12mS minimum
MTBF >100,000 Hours
Short Circuit Protection
Over Current Protection
Over Voltage Protection
Over Temperature Protection
Input Under Voltage Protection
Power Failure Alarm
No Load Operation
Operating Temperature: 0℃ to 50℃
Non-Operating Temperature: -40℃ to 70℃
Operating Humidity: 20 to 90 %
Harmonic: Meet EN6 1000-3-2 standards
EMI/RFI: CE, FCC class A and CISPR class A
Safety: UL, cUL, CB, TUV, CCC, FCC, CE, BSMI
RoHS and REACH compliant
Input and Output Rating
Input
|
Output
|
Voltage
|
Frequency
|
Current
|
Wattage
|
Load
|
+12V
|
+12Vsb
|
90-264Vac
|
47-63Hz
|
10~4A
|
800W
|
Max. Load
|
66A
|
3A
|
- Total output shall not exceed 800W
|
|
|